Isharyanti, Muty and Feisal Rinaldi, Sonny and Riyani, Ani and Merdekawati, Fusvita (2020) Verifikasi Metode CHOD-PAP Pada Pemeriksaan Kadar Kolesterol Total Menggunakan Fotometer Kenzamax. Diploma thesis, Politeknik Kesehatan Kemenkes Bandung.
Text
1.Cover.docx Download (117kB) |
|
Text
2. Lembar Pengesahan.docx Download (277kB) |
|
Text
3.Abstrak.docx Restricted to Repository staff only Download (36kB) |
|
Text
4.Kata Pengantar.docx Download (19kB) |
|
Text
5. Daftar Isi.docx Download (28kB) |
|
Text
9. BAB I.docx Download (23kB) |
|
Text
10. BAB II.docx Restricted to Repository staff only Download (523kB) |
|
Text
11. BAB III.docx Restricted to Repository staff only Download (33kB) |
|
Text
12. BAB IV.docx Restricted to Repository staff only Download (281kB) |
|
Text
13. BAB V.docx Download (20kB) |
|
Text
14. Daftar Pustaka.docx Download (21kB) |
Abstract
ABSTRAK Sebagai komponen penting dalam pelayanan kesehatan, hasil pemeriksaan laboratorium harus selalu terjamin mutunya. Verifikasi metode merupakan bagian dari pemantapan mutu, verifikasi metode dilakukan pada metode standar yang telah tervalidasi hal tersebut dilakukan kerena setiap laboratorium memiliki karateristik dan kondisi yang berbeda-beda. Di kampus Jurusan Analis Kesehatan Poltekkes Kemenkes Bandung rutin dilakukan pemeriksaan kadar kolesterol total menggunakan metode standar yaitu CHOD-PAP menggunakan fotometer kenzamax, akan tetapi penggunaan metode tersebut belum terverifikasi. Tujuan dari penelitian ini adalah untuk mengetahui kinerja dari metode CHOD-PAP menggunakan fotometer kenzamax apakah diterima atau tidak merujuk pada hasil parameter uji (presisi, bias dan total error). Dilakukan kontrol harian dengan menggunakan kontrol serum normal dan highpathologist sebagai sample dengan 5 kali pengulangan pada masing-masing level selama 5 hari. Data yang diperoleh diolah dengan menggunakan Microsoft Excel. Dari pemeriksaan tersebut didapatkan hasil uji presisi pada kontrol normal 0,8% dan kontrol highpathologist 0,5%; uji bias pada kontrol normal 1,5% dan kontrol highpathologist 0,1% ; total error pada kontrol normal 3 % dan kontrol highpathologist 1,2 . Maka semua kriteria parameter uji terpenuhi persyaratannya sehingga metode CHOD-PAP yang digunakan pada fotometer kenzamax kinerjanya dapat diterima. Kata kunci : Verifikasi, CHOD-PAP, kenzamax ABSTRACT As an important component in health care, laboratory results must always be guaranteed quality. Method verification is part of strengthening quality, method verification is carried out on a standardized method that has been validated because each laboratory has different characteristics and conditions. On the campus of the Medical Laboratory Technology Poltekkes Ministry of Health Bandung, routine checks for total cholesterol using the standard method CHOD-PAP using a kenzamax photometer, but the use of these methods has not been verified. The purpose of this study was to determine the performance of the CHOD-PAP method using a kenzamax photometer whether or not to refer to the results of the test parameters (precision, bias, and total error). Daily control was carried out using normal serum control and high pathologist as samples with 5 repetitions at each level for 5 days. The data obtained is processed using Microsoft Excel. From the examination, it was obtained the results of the precision test at 0.8% normal control and 0.5% high pathologist control; bias test at 1.5% normal control and 0.1% high pathologist control; the total error in the normal control was 3% and the high pathologist control 1.2%. Then all the criteria for the test parameters are met so that the CHOD-PAP method used on the kenzamax photometer has acceptable performance. Keyword: Verification CHOD-PAP, Kenzamax
Item Type: | Thesis (Diploma) |
---|---|
Subjects: | 600 Teknologi dan Ilmu-ilmu Terapan > 610 - 619 Ilmu Kedokteran dan Ilmu Pengobatan > 616 Penyakit |
Divisions: | Jurusan Teknik Laboratorium Medik > DIII |
Depositing User: | Muty Isharyanti |
Date Deposited: | 30 Sep 2020 14:37 |
Last Modified: | 30 Sep 2020 14:37 |
URI: | http://repo.poltekkesbandung.ac.id/id/eprint/934 |
Actions (login required)
View Item |