OPTIMASI KONSENTRASI PRIMER DAN SUHU ANNEALING UNTUK DETEKSI DNA Plasmodium falciparum METODE REAL-TIME PCR

Sari, Yunita and Djuminar, Ai and Hardiana, Acep Tantan and Merdekawati, Fusvita (2020) OPTIMASI KONSENTRASI PRIMER DAN SUHU ANNEALING UNTUK DETEKSI DNA Plasmodium falciparum METODE REAL-TIME PCR. Diploma thesis, Politeknik Kesehatan Kemenkes Bandung.

[img] Text
1. COVER.pdf

Download (174kB)
[img] Text
2. LEMBAR PENGESAHAN PEMBIMBING.pdf

Download (718kB)
[img] Text
3. LEMBAR PENGESAHAN PENGUJI.pdf

Download (699kB)
[img] Text
4. ABSTRAK.pdf

Download (352kB)
[img] Text
5. KATA PENGANTAR.pdf

Download (260kB)
[img] Text
6. DAFTAR ISI.pdf

Download (388kB)
[img] Text
11. BAB I.pdf

Download (279kB)
[img] Text
12. BAB II.pdf
Restricted to Repository staff only

Download (774kB)
[img] Text
13. BAB III.pdf
Restricted to Repository staff only

Download (271kB)
[img] Text
14. BAB IV.pdf
Restricted to Repository staff only

Download (571kB)
[img] Text
15. BAB V.pdf

Download (255kB)
[img] Text
16. DAFTAR PUSTAKA.pdf

Download (379kB)
[img] Text
Surat Publikasi Yunita.pdf

Download (797kB)

Abstract

Malaria merupakan suatu penyakit infeksi akut maupun kronik yang disebakan oleh infeksi Plasmodium spp. Salah satu jenis spesies Plasmodium yang bertanggungjawab atas sebagian besar angka mortalitas akibat malaria adalah Plasmodium falciparum. Saat ini, metode Real-Time PCR (Polymerase Chain Reaction) menjadi metode alternatif pemeriksaan malaria karena lebih sensitif dan spesifik dibandingkan metode mikroskopis dan Rapid Diagnostic Test (RDT). Kinerja metode Real-Time PCR ini perlu dilakukan optimalisasi sebelum melakukan pengujian, diantaranya optimasi konsentrasi primer dan suhu annealing. Kedua komponen tersebut perlu dioptimasi agar pengujian lebih sensitif dan spesifik. Tujuan penelitian ini adalah untuk mengetahui rentang konsentrasi primer dan rentang suhu annealing yang optimal dan paling umum digunakan untuk deteksi Plasmodium falciparum dengan menggunakan Real-Time PCR dari hasil studi literatur. Penelitian ini menggunakan metode Systematic Literature Review (SLR) dengan melakukan pencarian data sekunder menggunakan database elektronik Google Scholar, NCBI, PubMed, Malaria Journal, Scientific Reports, JEM dan PLOS One. Didapatkan 7 jurnal penelitian yang memiliki kesamaan tema penelitian dan dapat mewakili tujuan penelitian sehingga dimasukan dalam proses review. Analisis data dilakukan dengan metode analisis deskriptif. Berdasarkan hasil studi literatur ini, didapatkan rentang konsentrasi primer forward dan reverse yang optimal dan paling umum digunakan untuk deteksi Plasmodium falciparum yaitu mulai dari 1 μM hingga 2 μM dengan rentang suhu annealing yaitu mulai dari 47°C hingga 55°C. Malaria is an acute and chronic infectious diseases caused by Plasmodium spp. One of the species of Plasmodium that is responsible for most of the mortality due to malaria is Plasmodium falciparum. At present, the Real-Time PCR (Polymerase Chain Reaction) method is an alternative method for malaria testing because it is more sensitive and specific than the microscopic method and the Rapid Diagnostic Test (RDT). The performance of Real-Time PCR method needs to be optimized before testing, including optimization of primer concentration and annealing temperature. Both of these components need to be optimized so that testing is more sensitive and spesific. The purpose of this study is to determine the most optimal and commonly used of primer concentration and annealing temperature range on detecting Plasmodium falciparum by using Real-Time PCR from the results of literature studies. This research uses the Systematic Literature Review (SLR) method by searching secondary data using an electronic database of Google Scholar, NCBI, PubMed, malaria Journal, Scientific Reports, JEM and PLOS One. In 7 research journals have the same research theme and represent the research objectives so that they are included in the review process. Data analysis was performed using descriptive analysis method. Based on the results of this literature study, the most optimal and commonly used of the forward and reverse primer for Plasmodium falciparum detection are from 1 μM to 2 μM with annealing temperature ranging from 47°C to 55°C.

Item Type: Thesis (Diploma)
Subjects: 600 Teknologi dan Ilmu-ilmu Terapan > 610 - 619 Ilmu Kedokteran dan Ilmu Pengobatan > 616 Penyakit
Divisions: Jurusan Teknik Laboratorium Medik > D IV
Depositing User: Yunita Sari
Date Deposited: 26 Sep 2020 04:40
Last Modified: 26 Sep 2020 04:40
URI: http://repo.poltekkesbandung.ac.id/id/eprint/708

Actions (login required)

View Item View Item