Penentuan Kadmium Menggunakan Metode Paper Analytical Device (PAD) Dengan Teknik Pencitraan Digital Dalam Sampel Makanan

Rismiarti, Zuri (2018) Penentuan Kadmium Menggunakan Metode Paper Analytical Device (PAD) Dengan Teknik Pencitraan Digital Dalam Sampel Makanan. Jurnal Ilmiah Sains, 18 (1). pp. 10-17. ISSN 2540-9840

[img] Text
Penentuan Kadmium Menggunakan Metode Paper Analytical Device.pdf

Download (166kB)
Official URL: https://ejournal.unsrat.ac.id/index.php/JIS/articl...

Abstract

PENENTUAN KADMIUM MENGGUNAKAN METODE PAPER ANALYTICAL DEVICE (PAD) DENGAN TEKNIK PENCITRAAN DIGITAL DALAM SAMPEL MAKANANABSTRAKKadmium merupakan salah satu logam berat dari sepuluh bahan kimia berbahaya dan menjadi perhatian kesehatan masyarakat. Kadmium (Cd(II)) bukan merupakan logam esensial dalam tubuh manusia maupun tumbuhan dan hewan yang berdampak kronis bagi kesehatan dan lingkungan. Berbagai metode telah banyak dikembangkan untuk mendeteksi kandungan kadmium dalam berbagai sampel. Salah satu metode yang dipelajari adalah paper analytical device berbasis kompleks Alizarin Red S. dengan analisis menggunakan teknik pencitraan digital. Metode ini menggunakan kertas Whatmann sebagai media sampel dan reagen pengkelat yang akan menghasilkan warna kuning sehingga dapat dianalis secara kolorimetri. Tujuan penelitian ini adalah menentukan kandungan Cd(II) dalam sampel makanan dengan metode PAD berbasis kompleks Alizarin Red S. Penelitian dilakukan di Laboratorium Kimia-Farmasi Universitas Ma Chung pada bulan Agustus-November 2017. Sampel yang digunakan adalah daun kangkung, ikan segar mujaer, lele, dan pindang tongkol dengan hasil analisis Cd(II) (mg/g) masing – masing secara berurutan adalah 0.139; 0.210; 0.341 0.409. Hasil pengujian metode ini juga dibandingkan dengan metode standar AAS (Atomic Absorption Spectrometer).Kata kunci: kertas, kadmium, makanan, pencitraan, digital DETERMINATION OF KADMIUM USING PAPER ANALYTICAL DEVICE (PAD) METHOD WITH DIGITAL IMAGING TECHNIQUE IN FOOD SAMPLEABSTRACTCadmium is one of a heavy metal from ten chemicals of major public health concern. Cadmium is not essential metal in the human body as well as animals, plants which acquire chronic impact for heath and the environment. Many methods have been developed to detect trace Cd(II) in various sample. One of that method is paper analytical device based on Alizarin Red S complex using digital color image analysis. The method used Whatmann Paper as a media sample and chelating reagents which produce yellow color complex that can analyze colorimetry. The purpose of this research of determination Cd(II) in food samples using PAD based on Alizarin Red S complex. The experiment was conducted at the Chemical-Pharmaceutical Laboratory, Ma Chung University in August-November 2017. Samples are convolvulus leaves, fresh fish like mujaer, catfish, cobs with the results of Cd(II) (mg/g) of each sample of 0.139; 0.210; 0.341 0.409 respectively. The result of the proposed methods is compared with standard method of AAS (atomic absorption spectrometer).Keywords : paper, cadmium, food, digital, color

Item Type: Article
Subjects: 600 Teknologi dan Ilmu-ilmu Terapan > 610 - 619 Ilmu Kedokteran dan Ilmu Pengobatan
Divisions: Jurusan Teknik Laboratorium Medik > D IV
Depositing User: Mrs Zuri Resmiati
Date Deposited: 22 Aug 2022 07:37
Last Modified: 22 Aug 2022 07:37
URI: http://repo.poltekkesbandung.ac.id/id/eprint/5793

Actions (login required)

View Item View Item